42 CFR 84.163
§ 84.163 Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements.
United States · 42 CFR — Public Health · Status: effective
Cite this
- Citation
- 42 CFR 84.163, § 84.163 Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201776
- Permanent ID
ys:prov:201776@1- SHA-256
722c43d345b0e25bbcf264d5d1f7e4a40df8d364cdc9918a2eb67b4166ada52e
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The completely assembled respirator will be worn in a chamber containing 0.1 ±0.025 percent isoamyl acetate vapor, the intake of the hose will be connected to a suitable source of respirable air, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.
(b) The test will be conducted at the minimum pressure with the maximum hose length and will be repeated at the maximum pressure with the minimum hose length.