§ 84.170 Air-purifying particulate respirators; description.

United States · 42 CFR — Public Health · Status: effective

Get this as JSONEmbed this
Cite this
Citation
42 CFR 84.170, § 84.170 Air-purifying particulate respirators; description, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201779
Permanent ID
ys:prov:201779@1
SHA-256
3879ded7657cd3d4a2bda79bdc010c5da4b786752ea56d10d9cb71a2b9f915fa

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Non-powered air-purifying particulate respirators (series N, R, and P). (1) Non-powered air-purifying particulate respirators utilize the wearer's negative inhalation pressure to draw the ambient air through the air-purifying filter elements (filters) to remove particulates from the ambient air. They are designed for use as respiratory protection against atmospheres with particulate contaminants at concentrations that are not immediately dangerous to life or health and that contain adequate oxygen to support life. (2) Non-powered air-purifying particulate respirators are classified into three series, N-, R-, and P-series. The N-series filters are restricted to use in those workplaces free of oil aerosols. The R- and P-series filters are intended for removal of any particulate that includes oil-based liquid particulates. (3) Non-powered air-purifying particulate respirators are classified according to the efficiency level of the filter(s) as tested according to the requirements of this part. (i) N100, R100, and P100 filters must demonstrate a minimum efficiency level of 99.97 percent. (ii) N99, R99, and P99 filters must demonstrate a minimum efficiency level of 99 percent. (iii) N95, R95, and P95 filters must demonstrate a minimum efficiency level of 95 percent. (b) Powered air-purifying particulate respirators (PAPR classes HE and PAPR100). (1) Powered air-purifying particulate respirators utilize a blower to move the ambient air through the air-purifying filter elements (filters) to remove particulate contaminants and deliver clean air to the respiratory inlet covering. They are designed for use as respiratory protection against atmospheres considered not immediately dangerous to life or health and that contain adequate oxygen to support life. (2) Powered air-purifying particulate respirators are classified into two classes, HE and PAPR100, and three series, HE, PAPR100-N, and PAPR100-P. The N-series filters are restricted to use in those workplaces free of oil aerosols. The P-series filters are intended for removal of any particulate that includes oil-based liquid particulates. (3) All three filter series, HE, PAPR100-N, and PAPR100-P, for powered air-purifying particulate respirators must demonstrate a minimum efficiency level of 99.97 percent.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.