yourstate.us
42 CFR 84.172

§ 84.172 Airflow resistance test.

United States · 42 CFR — Public Health · Status: effective

Get this as JSONEmbed this
Cite this
Citation
42 CFR 84.172, § 84.172 Airflow resistance test, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201781
Permanent ID
ys:prov:201781@1
SHA-256
ac9af512c0e243a73b860345f231d8f9ac0f6afbd34033953ecc7b70dc189c8e

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Resistance to airflow will be measured in the tight-fitting respiratory inlet covering of a complete particulate respirator mounted on a test fixture with air flowing at continuous rate of 85 ±2 liters per minute, before each test conducted in accordance with § 84.173. (b) Resistance of a complete tight-fitting powered air-purifying particulate respirator system will be measured with the blower off if the manufacturer indicates that the respirator should not be doffed in the event of a blower failure. (c) The maximum allowable resistance requirements for air-purifying particulate respirators are as follows: Maximum Resistance [mm water-column height]

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.