42 CFR 84.176

§ 84.176 Fit test—PAPR classes HE and PAPR100.

United States · 42 CFR — Public Health · Status: effective

Get this as JSONEmbed this
Cite this
Citation
42 CFR 84.176, § 84.176 Fit test—PAPR classes HE and PAPR100, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201785
Permanent ID
ys:prov:201785@1
SHA-256
33e2425a1ce552f65c98ce32e5ef7763c37cd60445fbc156902c17ec8c568a30

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

NIOSH will assess powered air-purifying respirator fit using either isoamyl acetate or generated aerosol. (a) Isoamyl acetate (IAA) fit test. The applicant must provide a charcoal-filled canister or cartridge of a size and resistance similar to the filter unit with connectors which can be attached to the facepiece in the same manner as the filter unit. (1) The canister or cartridge will be used in place of the filter unit, and persons will each wear a modified half-mask facepiece for 8 minutes in a test chamber containing 100 parts (by volume) of isoamyl acetate vapor per million parts of air. (i) The following work schedule will be performed by each wearer in the test chamber: (A) Two minutes nodding up and down, and turning head side to side; and (B) Two minutes calisthenic arm movements. (C) Two minutes running in place. (D) Two minutes pumping with tire pump. (ii) The facepiece must be capable of adjustment, according to the applicant's instructions, to each wearer's face, and the odor of isoamyl acetate must not be detectable by any wearer during the test. (2) Where the respirator is equipped with a full facepiece, hood, helmet, or mouthpiece, the canister or cartridge will be used in place of the filter unit, and persons will each wear the modified respiratory inlet covering for 8 minutes in a test chamber containing 500 parts (by volume) of isoamyl acetate vapor per million parts of air, performing the work schedule specified in paragraph (b)(2) of this section. (b) Generated aerosol fit test. The powered air-purifying particulate respirator system is tested in an atmosphere containing 20-40 mg/m 3 corn oil aerosol having a mass median aerodynamic diameter of 0.4 to 0.6 µm. (1) The following activities will be performed by each wearer in the test chamber: (i) Two minutes, nodding and turning head; (ii) Two minutes, calisthenic arm movements; (iii) Two minutes, running in place; and (iv) Two minutes, pumping with a tire pump into a 28-liter (1 ft 3) container. (2) The respiratory inlet covering will be adjusted, according to the applicant's instructions, to each wearer's face. (3) The appropriate fit factor must be exceeded during the entire test.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.