42 CFR 84.205
§ 84.205 Facepiece test; minimum requirements.
United States · 42 CFR — Public Health · Status: effective
Cite this
- Citation
- 42 CFR 84.205, § 84.205 Facepiece test; minimum requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201807
- Permanent ID
ys:prov:201807@1- SHA-256
9f8276d0c44409ecf2b9e9e4fcb2e3cfd1326ac741188993bd4685b7c893c3dc
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The complete chemical cartridge respirator will be fitted to the faces of persons having varying facial shapes and sizes.
(b) Where the applicant specifies a facepiece size or sizes for the respirator together with the approximate measurement of faces they are designed to fit, the Institute will provide test subjects to suit such facial measurements.
(c) Any chemical cartridge respirator part which must be removed to perform the facepiece or mouthpiece fit test shall be replaceable without special tools and without disturbing facepiece or mouthpiece fit.
(d) The facepiece or mouthpiece fit test using the positive or negative pressure recommended by the applicant and described in his instructions will be used before each test.
(e)(1) Each wearer will enter a chamber containing 100 p.p.m. isoamyl acetate vapor for half-mask facepieces, and 1,000 p.p.m. for full facepieces, mouthpieces, hoods, and helmets.
(2) The facepiece or mouthpiece may be adjusted, if necessary, in the test chamber before starting the test.
(3) Each wearer will remain in the chamber for 8 minutes while performing the following activities:
(i) Two minutes, nodding and turning head;
(ii) Two minutes, calisthenic arm movements;
(iii) Two minutes, running in place; and
(iv) Two minutes, pumping with a tire pump into a 28-liter (1 cubic-foot) container.
(4) Each wearer shall not detect the odor of isoamyl-acetate vapor during the test.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.