43 CFR 3174.7
§ 3174.7 LACT system—general requirements.
United States · 43 CFR — Public Lands: Interior · Status: effective
Cite this
- Citation
- 43 CFR 3174.7, § 3174.7 LACT system—general requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/212244
- Permanent ID
ys:prov:212244@1- SHA-256
bd8cbd86caf49bb513a7719dc0a8221c23deaf53cb5a23d61a328944cd8e808f
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) A LACT system must meet the construction and operation requirements and minimum standards of this section, § 3174.8, and § 3174.4.
(b) A LACT system must be proven as prescribed in § 3174.11 of this subpart.
(c) Measurement tickets must be completed under § 3174.12(b) of this subpart.
(d) All components of a LACT system must be accessible for inspection by the AO.
(e)(1) The operator must notify the AO, within 72 hours after discovery, of any LACT system failures or equipment malfunctions that may have resulted in measurement error.
(2) Such system failures or equipment malfunctions include, but are not limited to, electrical, meter, and other failures that affect oil measurement.
(f) Any tests conducted on oil samples extracted from LACT system samplers for determination of temperature, oil gravity, and S&W content must meet the requirements and minimum standards in § 3174.6(b)(2), (4), and (6) of this subpart.
(g) Automatic temperature compensators and automatic temperature and gravity compensators are prohibited.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.