46 CFR 10.306
§ 10.306 Hearing requirements.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 10.306, § 10.306 Hearing requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/223445
- Permanent ID
ys:prov:223445@1- SHA-256
c84c16ebaa426a666f69dd068f5cea9e65b6abd4b7729000d0ff69b265ff936b
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) If the medical practitioner conducting the general medical exam has concerns that an applicant's ability to hear may impact maritime safety, the examining medical practitioner must refer the applicant to an audiologist or other hearing specialist to conduct an audiometer test and a speech discrimination test, as appropriate.
(b) The audiometer test must include testing at the following thresholds: 500 Hz; 1,000 Hz; 2,000 Hz; and 3,000 Hz. The frequency responses for each ear must be averaged to determine the measure of an applicant's hearing ability. Applicants must demonstrate an unaided threshold of 30 decibels or less in at least one ear.
(c) The functional speech discrimination test must be carried out at a level of 65 decibels. For issuance of an original MMC or endorsement the applicant must demonstrate functional speech discrimination of at least 90 percent. For renewal or raise of grade, the applicant must demonstrate functional speech discrimination of at least 80 percent.
(d) Hearing waivers. An applicant who is unable to meet the hearing standards of the audiometer test, but who can pass the functional speech discrimination test; or who requires hearing aids to meet the hearing standards, may be eligible for a medical waiver in accordance with § 10.303 of this subpart.
(e) Hearing operational limitation. If hearing aids are required in order to meet the hearing standards above, a mariner may not serve under the authority of the endorsement unless hearing aids are worn in the operational mode, and spare batteries are carried onboard a vessel. This operational limitation will be placed on their medical certificate.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.