46 CFR 34.17-10
§ 34.17-10 Controls—T/ALL.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 34.17-10, § 34.17-10 Controls—T/ALL, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/224369
- Permanent ID
ys:prov:224369@1- SHA-256
d274bf26cbff58b3165a1079c386d92e2ee9ecd1a93ecd07c7a83c0072294bcf
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The foam agent, its container, measuring devices, and other items peculiar to the system shall be of an approved type.
(b) The foam-producing material container and all controls and valves for the operation of the system shall be outside the space protected and shall not be located in such space as might be cut off or made inaccessible in the event of fire in any of the spaces protected. The control space shall be as convenient as practicable to one of the main escapes from the spaces protected, and shall be marked as required by § 35.40-10 of this subchapter. Where pumps are required, it shall not be necessary that they be started from the control space.
(c) Complete, but simple instructions for the operation of the system shall be located in a conspicuous place at or near the controls.
(d) The valves to the various spaces served shall be marked as required by § 35.40-10 of this subchapter.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.