46 CFR 38.10-20

§ 38.10-20 Liquid level gaging devices—TB/ALL.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 38.10-20, § 38.10-20 Liquid level gaging devices—TB/ALL, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/224535
Permanent ID
ys:prov:224535@1
SHA-256
6dc5ced7bc86792208b1ab1cd5c3da1c22ace223f6efbe6985f945ab49dc32f3

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each tank shall be fitted with a liquid level gaging device of approved design to indicate the maximum level to which the tank may be filled with liquid: (1) Between −20 °F. and 130 °F. for unrefrigerated service; or, (2) Within the operating temperature range for tanks operating below atmospheric temperature. (b) Liquid level gaging devices may be of the following types: Rotary tube, slip tube, magnetic, automatic float, or similar types approved by the Commandant. Except as otherwise provided in this section, fixed tube devices are not acceptable as the primary gaging device. (c) All gaging devices shall be arranged so that the maximum liquid level for product being carried, to which the tank may be filled is readily determinable. The maximum gallonage capacity as required by § 38.15-1 shall be: (1) Marked on the tank system nameplate or gaging device; or, (2) Shown in the ullage tables. (d) Gaging devices that require bleeding of the product to the atmosphere, such as the rotary tube, fixed tube, and slip tube, shall be so designed that the bleed valve maximum opening is not larger than a No. 54 drill size (0.055-inch diameter), unless provided with an excess flow valve. (e) For pressure vessel type tanks each automatic float, continuous reading tape or similar type gage not mounted directly on the tank or dome shall be fitted with a shutoff device located as close to the tank as practicable. When an automatic float gaging device, which gages the entire height of the tank is used, a fixed tube gage set in the range of 85 percent to 90 percent of the water capacity of the tank shall be provided in addition as a means of checking the accuracy of the automatic float, gage, or other alternate means acceptable to the Commandant may be used. (f) A gaging device shall be designed for a pressure at least equal to the maximum allowable pressure of the tank on which it is installed. (g) Gage glasses of the columnar type are prohibited. (h) Flat sight glasses may be used in the design of automatic float continuous reading tape gages: Provided, That such glasses shall be made of high strength material suitable for the operating temperatures of not less than one-half inch in thickness and adequately protected by a metal cover.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.