46 CFR 42.20-55
§ 42.20-55 Trunks.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 42.20-55, § 42.20-55 Trunks, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/224700
- Permanent ID
ys:prov:224700@1- SHA-256
b22aec565ddc491e524372794b50f53c45bcbdf202839b786684c2da15bbdb8f
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) A trunk or similar structure which does not extend to the sides of the vessel shall be regarded as efficient on the following conditions:
(1) The trunk is at least as strong as a superstructure;
(2) The hatchways are in the trunk deck, and the hatchway coamings and covers comply with the requirements of §§ 42.15-15 to 42.15-30, inclusive, and the width of the trunk deck stringer provides a satisfactory gangway and sufficient lateral stiffness; however, small access openings with watertight covers may be permitted in the freeboard deck;
(3) A permanent working platform fore and aft fitted with guard rails is provided by the trunk deck, or by detached trunks connected to superstructures by efficient permanent gangways;
(4) Ventilators are protected by the trunk by watertight covers or by other equivalent means;
(5) Open rails are fitted on the weather parts of the freeboard deck in way of the trunk for at least half their length;
(6) The machinery casings are protected by the trunk, by a superstructure of at least standard height, or by a deckhouse of the same height and of equivalent strength;
(7) The breadth of the trunk is at least 60 percent of the breadth of the vessel; and,
(8) Where there is no superstructure, the length of the trunk is at least 0.6L.
(b) The full length of an efficient trunk reduced in the ratio of its mean breadth to B shall be its effective length.
(c) The standard height of a trunk is the standard height of a superstructure other than a raised quarter deck.
(d) Where the height of a trunk is less than the standard height, its effective length shall be reduced in the ratio of the actual to the standard height. Where the height of hatchway coamings on the trunk deck is less than that required under § 42.15-25(a), a reduction from the actual height of trunk shall be made which corresponds to the difference between the actual and required height of coaming.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.