46 CFR 45.149
§ 45.149 Machinery space openings.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 45.149, § 45.149 Machinery space openings, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/224807
- Permanent ID
ys:prov:224807@1- SHA-256
f532b2c4fdc4b156bf6e68e44a7926dae141b7ad99572a8f0fc582b17c5a34c1
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Machinery space openings in position 1 or 2 must be framed and enclosed by steel casings, and where the casings are not protected by other structures that meet the requirements of § 45.109, their strength must be approved by the Commandant or the assigning authority.
(b) Access openings in casings required by paragraph (a) of this section must have doors complying with the requirements of § 45.113. Other openings in such casings shall be fitted with equivalent covers, permanently attached.
(c) Except as provided in paragraph (d) of this section, coamings of any funnel or machinery space ventilator that must be kept open for the essential operations of the ship must—
(1) In position 1, extend at least 12.5 ft above the deck; and
(2) In position 2, extend at least 6 ft above the deck.
(d) The Commandant may approve a lesser height for protected coamings.
(e) Coamings of any fiddley or skylight over a machinery space opening in the freeboard or superstructure deck or the top of a deckhouse on the freeboard deck, must have covers of steel permanently attached and capable of being secured weathertight.
Legislative history