yourstate.us
46 CFR 52.25-10

§ 52.25-10 Organic fluid vaporizer generators (modifies PVG-1 through PVG-12).

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 52.25-10, § 52.25-10 Organic fluid vaporizer generators (modifies PVG-1 through PVG-12), United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/224956
Permanent ID
ys:prov:224956@1
SHA-256
c1d7ab8805e48a1c9bed4fe4e2bc3723c70bee21c0ae9f9b21b1c5e5e767ebf5

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Organic fluid vaporizers must meet the requirements of PVG-1 through PVG-12 of Section I of the ASME BPVC (incorporated by reference; see § 52.01-1). (b) The Commandant must approve the application and end use of organic fluid vaporizer generators.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.