46 CFR 58.20-15
§ 58.20-15 Installation of refrigerating machinery.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 58.20-15, § 58.20-15 Installation of refrigerating machinery, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/225235
- Permanent ID
ys:prov:225235@1- SHA-256
34f1762d37e046ff607b36437201b5e97f4c5a262eb8aa429d1595dac033f82d
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Where refrigerating machines are installed in which anhydrous ammonia is used as a refrigerant, such machines must be located in a well-ventilated, isolated compartment, preferably on the deck, but in no case is it permissible to install such machines in the engine room space unless the arrangement is such as to eliminate any hazard from gas escaping to the engine room. Absorption machines using a solution of aqua ammonia and machines using carbon dioxide are exempt from this requirement, provided the maximum charges that might be released in the event of breakage do not exceed 300 pounds.
(b) Machinery compartments containing equipment for ammonia must be fitted with a sprinkler system providing an effective water spray and having a remote-control device located outside the compartment.
(c) All refrigeration compressor spaces must be effectively ventilated and drained and must be separated from the insulated spaces by a watertight bulkhead, unless otherwise approved.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.