yourstate.us
46 CFR 58.20-20

§ 58.20-20 Refrigeration piping.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 58.20-20, § 58.20-20 Refrigeration piping, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/225236
Permanent ID
ys:prov:225236@1
SHA-256
c49e04d2ca73117a284f64d5ecf4324c25e2e9b7da782e313953d407d8c2fdcf

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) All piping materials must be suitable for handling the primary refrigerant, brine, or fluid used, and must be of such chemical and physical properties as to remain ductile at the lowest operating temperature. (b) Piping systems must be designed in accordance with ASME B31.5 (incorporated by reference; see § 58.03-1). Piping used for cargo reliquefaction systems must also comply with the applicable requirements found in low temperature piping, § 56.50-105 of this subchapter. (c) A relief valve must be fitted on or near the compressor on the gas discharge side between the compressor and the first stop valve with the discharge therefrom led to the suction side. A check valve must be fitted in the atmospheric discharge line if it is led through the side of the vessel below the freeboard deck, or a shutoff valve may be employed if it is locked in the open position.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.