yourstate.us
46 CFR 58.30-5

§ 58.30-5 Design requirements.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 58.30-5, § 58.30-5 Design requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/225259
Permanent ID
ys:prov:225259@1
SHA-256
e5e78e038b67331701ec760dc73badaa3c9ccf6e79d579b674b985a509a319db

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) The requirements of part 56 of this subchapter are also applicable to piping and fittings in fluid power and control systems listed in § 58.30-1, except as modified herein. The designer should consider the additional pressure due to hydraulic shock. (b) The system must be so designed that proper functioning of any unit must not be affected by the back pressure in the system. The design must be such that malfunctioning of any unit in the system will not render any other connected or emergency system inoperative because of back pressure. (c) Pneumatic systems with a maximum allowable working pressure in excess of 150 psi must be designed with a surge tank or other acceptable means of pulsation dampening. (d) Each pneumatic system must minimize the entry of oil into the system and must drain the system of liquids.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.