46 CFR 64.91

§ 64.91 Relief valve for the cargo pump discharge.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 64.91, § 64.91 Relief valve for the cargo pump discharge, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/225458
Permanent ID
ys:prov:225458@1
SHA-256
6ebac6b6d0effe34a534ca7a6841f2830f86ff901b07c1259298d4bd028f358a

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

The cargo pump discharge must have a relief valve that is— (a) Fitted between the cargo pump discharge and the shut-off valve, with the relief valve discharge piped back to the cargo pump suction or returned to the tank; and (b) Set at the maximum design pressure of the piping and discharge hose, or less.