§ 76.27-20 Alarm indicators.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 76.27-20, § 76.27-20 Alarm indicators, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/225989
- Permanent ID
ys:prov:225989@1- SHA-256
0ab2e452eed1dfdd1bcf9025b123e648bcc4058bbc219ee6c6e90514eb322014
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Audible alarms must generate sound pressure levels as set forth in 46 CFR 161.002 and must:
(1) Be at least 75 dBA as measured at the sleeping position in cabins;
(2) Be at least 10 dBA above ambient noise levels existing during normal operation with the ship under way in moderate weather when measured at a point 5 feet (1.5 meters) above the finished floor and at least 3 feet (1 meter) from the source;
(3) Not exceed 120 dBA; and
(4) The sound pressure level must be measured in the third octave band about the fundamental frequency.
(b) Visual alarms must generate light of an intensity and period as set forth in 46 CFR 161.002.
(c) All audible and visual alarms must be audible and visible throughout the spaces they are intended to alert.