46 CFR 92.15-10
§ 92.15-10 Ventilation for closed spaces.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 92.15-10, § 92.15-10 Ventilation for closed spaces, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226356
- Permanent ID
ys:prov:226356@1- SHA-256
6bf535a23770200feb8a39d68cddf019c5f1dbc3eb8cedeef0bac6aa72b2ba34
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Except as noted in paragraph (c) of this section, all enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators.
(b) Means shall be provided for stopping all fans in ventilation systems serving machinery and cargo spaces and for closing all doorways, ventilators and annular spaces around funnels and other openings to such spaces, from outside these spaces, in case of fire.
(c) On unmanned cargo barges not fitted with a fixed bilge system, vents and ventilators may be omitted from void spaces.
(d) The ventilation of spaces that are “specially suitable for vehicles” shall be in accordance with §§ 97.80-1, 111.105-39 and 111.105-40 of this chapter, as applicable.
(1) Areas below the weather deck shall be provided with continuous pressure-positive ventilation at each level on which vehicles are transported.
(2) The quantity of ventilating air shall be not less than 1 cubic foot per minute per square foot of deck area.
(3) The ventilation system shall be such as to prevent air stratification as well as to prevent the accumulation of air pockets.
(4) An alarm system shall be provided which will indicate the loss of required ventilation. The alarm location shall be in a normally manned space acceptable to the Commandant.
(e) For requirements regarding controls of electrically powered ventilation systems, see subchapter J (Electrical Engineering) of this chapter.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.