46 CFR 98.25-50

§ 98.25-50 Filling and discharge pipes.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 98.25-50, § 98.25-50 Filling and discharge pipes, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226604
Permanent ID
ys:prov:226604@1
SHA-256
9a1e18a7f31eded98a2aeb674ae473a7bd830d1129304b480259e44507f3bd42

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Filling connections shall be provided with one of the following: (1) Combination back pressure check valve and excess flow valve; (2) One double or two single back pressure check valves; or (3) A positive shut-off valve in conjunction with either an internal back pressure check valve or an internal excess flow valve. (b) All other liquid and vapor connections to tanks, except filling connections, safety relief valves, and liquid level gaging devices and pressure gages described in § 98.25-40(e) and (f) shall be equipped with automatic excess flow valves; or in lieu thereof, may be fitted with quick closing internal stop valves, which, except during filling and discharge operations, shall remain closed. The control mechanism for such valves shall be provided with a secondary remote control of a type acceptable to the Commandant. (c) The excess flow, internal stop or back pressure check valves shall be located on the inside of the tank or outside where the piping enters the tank. In the latter case, installation shall be made in such a manner that any undue strain will not cause breakage between the tank and the excess flow or internal stop valve. (d) Where the filling and discharge are made through a common nozzle at the tank, and the connection is fitted with a quick-closing internal stop valve as permitted in paragraph (b) of this section, the back pressure check valve or excess flow valve is not required, provided, however, a positive shut-off valve is installed in conjunction with the internal stop valve.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.