§ 98.30-37 Firefighting requirements.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 98.30-37, § 98.30-37 Firefighting requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226643
- Permanent ID
ys:prov:226643@1- SHA-256
66717b9ba116fa43c0d3da467381388f2aaa48c77ddceadee279d93af389c383
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
No person may lift a portable tank on or off a vessel, or transfer a product with a flashpoint of less than 300 °F to or from a portable tank or IBC unless—
(a) Water pressure is maintained on the firemain;
(b) Firehoses, fitted with a Coast Guard-approved combination nozzle, are attached to each fire hydrant in the vicinity of the portable tanks;
(c) Except as provided in § 98.30-39, fire extinguishers of a dry chemical type are—
(1) Located to protect the deck area 10 feet in any horizontal direction from each portable tank and its associated cargo handling system;
(2) Coast Guard approved; and
(3) Capable of covering the deck area without being moved;
(d) In a deck area of 500 square feet or less, there are two or more dry chemical fire extinguishers of 300 pounds or more total capacity of extinguishing agent; and
(e) In a deck area of more than 500 square feet, there are three or more dry chemical fire extinguishers of 450 pounds or more total capacity of extinguishing agent.