46 CFR 108.239
§ 108.239 Fuel transfer equipment.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 108.239, § 108.239 Fuel transfer equipment, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226779
- Permanent ID
ys:prov:226779@1- SHA-256
98cae74cb5f926b487a2d288b98e27251b7de2c031b13e17fdde56cfb0d91bd3
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each nozzle must be a “deadman” type.
(b) Each hose must have a storage reel.
(c) Each hose must have a static grounding device.
(d) Each electric fuel transfer pump must have a control with a fuel transfer pump operation indicator light at the pump.
(e) There must be a fuel pump shut off at each of the access routes required by § 108.235(f).
(f) Each fuel transfer pump and each hose reel must have a means to contain fuel spills or leaks.
(g) Each hose must meet chapter 3 “Aircraft Fueling Hose” of National Fire Protection Association Standard for Aircraft Fuel Servicing (N.F.P.A. No. 407-1975).
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.