§ 108.429 Fire main system protection.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 108.429, § 108.429 Fire main system protection, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226800
- Permanent ID
ys:prov:226800@1- SHA-256
e282623a0eeb6bbdb4961434a411ff2ae7d000def96ed565d936f63879550041
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each pipe and fire hydrant in a fire main system must be installed to the extent practicable in locations that are not exposed to damage by materials that are moved on or onto the deck.
(b) Each part of the fire main system located on an exposed deck must either be protected against freezing or be fitted with cutout valves and drain valves to shut off and drain the entire exposed system in freezing weather.