yourstate.us
46 CFR 108.455

§ 108.455 Enclosure openings.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 108.455, § 108.455 Enclosure openings, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226815
Permanent ID
ys:prov:226815@1
SHA-256
477a5105b317bf18e1a1c511302615ee1a32658409bca4683a7a601c668aee75

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Mechanical ventilation for spaces protected by a CO2 system must be designed to shut down automatically when the system is activated. (b) Each space that is protected by a CO2 system and that has natural ventilation must have a means for closing that ventilation. (c) Each space protected by a CO2 system must have the following means for closing the openings to the space from outside the space: (1) Doors, shutters, or dampers for closing each opening in the lower portion of the space. (2) Doors, shutters, dampers or temporary means such as canvas or other material normally on board a unit may be used for closing each opening in the upper portion of the space.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.