§ 108.459 Number and location of outlets.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 108.459, § 108.459 Number and location of outlets, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226818
- Permanent ID
ys:prov:226818@1- SHA-256
2a8392840ef71e27d36c19f53664f675334e88c720ae8f9b8d1e8606449a27d1
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) A foam extinguishing system in a space must have enough outlets to spread a layer of foam of uniform thickness over the deck or bilge areas of the space.
(b) A foam extinguishing system in a space that has a boiler on a flat that is open to or can drain into a lower portion of the space must have enough outlets to spread a layer of foam of uniform thickness over the—
(1) Flat; and
(2) Deck or bilge areas of the space.
(c) A foam extinguishing system for a tank must have enough outlets to spread a layer of foam of uniform thickness over the surface of the liquid in the tank.