46 CFR 108.515
§ 108.515 Requirements for units built before October 1, 1996.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 108.515, § 108.515 Requirements for units built before October 1, 1996, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/226841
- Permanent ID
ys:prov:226841@1- SHA-256
10212d8f9ebad453f03536b1b3f16230b551be9fca779d034d29ffaeaedf3c8f
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Units which were constructed prior to October 1, 1996, must—
(1) By October 1, 1997, have either—
(i) Lifeboats and liferafts that meet § 108.525; or
(ii) Totally enclosed fire-protected lifeboats of sufficient capacity to accommodate 100 percent of the persons permitted on board, plus additional totally enclosed lifeboats or davit-launched liferafts of sufficient capacity to accommodate 100 percent of the persons permitted on board the unit. The following exceptions apply:
(A) An open lifeboat may be used instead of davit-launched liferafts as long as it is in good working order. An open lifeboat requiring extensive repairs must be replaced with either a totally enclosed fire-protected lifeboat, or davit-launched liferafts.
(B) A submersible unit constructed before January 3, 1979, may continue to use the lifesaving arrangements described on the units Certificate of Inspection in effect on October 1, 1996.
(2) By October 1, 1997, fit retro-reflective material on all floating appliances, lifejackets, and immersion suits.
(3) Except for the requirements in paragraphs (a)(1) and (a)(2) of this section, units may retain the arrangement of lifesaving appliances previously required and approved for the unit, as long as the arrangement or appliance is maintained in good condition to the satisfaction of the OCMI.
(b) When any lifesaving appliance or arrangement on a unit subject to this part is replaced, or when the unit undergoes repairs, alterations or modifications of a major character involving replacement of, or any addition to, the existing lifesaving appliances or arrangements, each new lifesaving appliance and arrangement must meet the requirements of this part, unless the OCMI determines that the unit cannot accommodate the new appliance or arrangement, except that—
(1) A survival craft is not required to meet the requirements of this part if it is replaced without replacing its davit and winch; and
(2) A davit and its winch are not required to meet the requirements of this part if one or both are replaced without replacing the survival craft.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.