§ 111.05-31 Grounding conductors for systems.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.05-31, § 111.05-31 Grounding conductors for systems, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227010
Permanent ID
ys:prov:227010@1
SHA-256
dba8796abf7af1662d92c7c1efcce91c14c8dbd8920362f7b59b8f4f3fe41350

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) A conductor for grounding a direct-current system must be the larger of: (1) The largest conductor supplying the system; or (2) No. 8 AWG (8.4mm 2). (b) A conductor for grounding the neutral of an alternating-current system must meet Table 111.05-31(b). Table 111.05-31(b)—Neutral Grounding Conductor for Alternating-Current System