yourstate.us
46 CFR 111.05-37

§ 111.05-37 Overcurrent devices.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.05-37, § 111.05-37 Overcurrent devices, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227012
Permanent ID
ys:prov:227012@1
SHA-256
20138c9c0f75baa4d569ac70219662e61d85ddabd29362f9caa81d213d9c815a

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) A permanently grounded conductor must not have an overcurrent device unless the overcurrent device simultaneously opens each ungrounded conductor of the circuit. (b) The neutral conductor of the emergency-main switchboard bus-tie must not have a switch or circuit breaker.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.