§ 111.40-15 Overcurrent device.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 111.40-15, § 111.40-15 Overcurrent device, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227074
- Permanent ID
ys:prov:227074@1- SHA-256
f363dc30607fdf22d12f63f8b3e4ffd4d2316eddc2349d259bacf3173e280187
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
The total load on any overcurrent device located in a panelboard must not exceed 80 percent of its rating if, in normal operation, the load will continue for 3 hours or more; except if the assembly, including the overcurrent device, is rated for continuous duty at 100% of its rating.