§ 111.60-4 Minimum cable conductor size.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.60-4, § 111.60-4 Minimum cable conductor size, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227104
Permanent ID
ys:prov:227104@1
SHA-256
c463c38ead96d78b7ca8763b60e4046be66fab82e141da454132425764dad843

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Each cable conductor must be 18 AWG (0.82 mm 2) or larger except— (a) Each power and lighting cable conductor must be 14 AWG (2.10 mm 2) or larger; and (b) Each thermocouple, pyrometer, or instrumentation cable conductor must be 22 AWG (0.33 mm 2) or larger.