yourstate.us
46 CFR 111.60-11

§ 111.60-11 Wire.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.60-11, § 111.60-11 Wire, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227109
Permanent ID
ys:prov:227109@1
SHA-256
eec98fd8484b9290be3dd72c4a1139e607f32efe79275eb543a81b73ab7f7378

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Wire must be in an enclosure. (b) Wire must be component insulated. (c) Wire, other than in switchboards, must meet the requirements in ANSI/UL 44, ANSI/UL 83, MIL-DTL-76E (all three standards incorporated by reference; see § 110.10-1 of this subchapter), or equivalent standard. (d) Switchboard wire must meet subpart 111.30 of this part. (e) Wire must be of the copper stranded type.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.