yourstate.us
46 CFR 111.75-1

§ 111.75-1 Lighting feeders.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.75-1, § 111.75-1 Lighting feeders, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227121
Permanent ID
ys:prov:227121@1
SHA-256
f5641793309f2e5623f1c25f66dfbf3bc65349a11e5087fe20f9c4a2d8fd7b16

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Passenger vessels. On a passenger vessel with fire bulkheads forming main vertical and horizontal fire zones, the lighting distribution system, including low location egress lighting where installed, must be arranged so that, to the maximum extent possible, a fire in any main vertical and horizontal fire zone does not interfere with the lighting in any other fire zone. This requirement is met if main and emergency feeders passing through any zone are separated both vertically and horizontally as widely as practicable. (b) Machinery spaces. Lighting for enginerooms, boilerrooms, and auxiliary machinery spaces must be supplied from two or more feeders. One of these feeders must be a ship's service feeder. Special requirements for emergency lighting, feeders, and branch circuits are in subpart 112.43 of this chapter.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.