46 CFR 111.95-3
§ 111.95-3 General requirements.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 111.95-3, § 111.95-3 General requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227154
- Permanent ID
ys:prov:227154@1- SHA-256
da67f7328d063516093462d4a27979061e77489d128b227050715550da0752d8
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each electrical component (e.g., enclosure, motor controller, or motor) must be constructed to the appropriate NEMA or IEC degree of protection requirement for the service and environment in which it is installed.
(b) Each main line emergency disconnect switch, if accessible to an unauthorized person, must have a means to lock the switch in the open-circuit position with a padlock or its equivalent. The switch must not lock in the closed-circuit position.