§ 111.97-7 Distribution.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.97-7, § 111.97-7 Distribution, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227160
Permanent ID
ys:prov:227160@1
SHA-256
859b484f62c5fb0b2a4a0e0b5af572b0e61cf16ccc0367fd9abba2aac9f6c29f

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each distribution panelboard for a watertight door system must be above the uppermost continuous deck and must have means for locking. (b) Each feeder supplying a watertight door operating system must be above the uppermost continuous deck. (c) Each watertight door operating system must have a separate branch circuit.