§ 111.103-1 Power ventilation systems except machinery space ventilation systems.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.103-1, § 111.103-1 Power ventilation systems except machinery space ventilation systems, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227170
Permanent ID
ys:prov:227170@1
SHA-256
cacda2f76f9b8968b682072f9d93fbe69e68ce9365c7a1615e7b433a554166b3

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Each power ventilation system that is not a machinery space ventilation system must have: (a) A control to stop the ventilation that is: (1) Outside the space ventilated; and (2) Grouped with the controls for every power ventilation system to which this section is applicable; and (b) In addition to the control required by paragraph (a), a stop control that is: (1) As far as practicable from the control required by paragraph (a) and grouped with the controls for every power ventilation system to which this section is applicable; or (2) The circuit breakers for ventilation grouped on the main switchboard and marked, “In Case of Fire Trip to Stop Ventilation.” The requirements of this section do not apply to closed ventilation systems for motors or generators, diffuser fans for refrigerated spaces, room circulating fans, or exhaust fans for private toilets of an electrical rating comparable to that of a room circulating fan.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.