§ 111.103-7 Ventilation stop stations.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 111.103-7, § 111.103-7 Ventilation stop stations, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227172
Permanent ID
ys:prov:227172@1
SHA-256
a390e64c920c4b049c55053ed3c50c507ccc5409b39beebf77ae89229ca33a2b

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Each power ventilation system stop station must: (a) Be protected by an enclosure with a glass-paneled door on the front; (b) Be marked, “In Case of Fire Break Glass and Operate Switch to Stop Ventilation;” (c) Have the “stop” position of the switch clearly identified; (d) Have a nameplate that identifies the system controlled; and (e) Be arranged so that damage to the switch or cable automatically stops the equipment controlled.