46 CFR 111.105-50
§ 111.105-50 Alternative standard to the classification of hazardous locations requirements of this subchapter.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 111.105-50, § 111.105-50 Alternative standard to the classification of hazardous locations requirements of this subchapter, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227198
- Permanent ID
ys:prov:227198@1- SHA-256
fb2b34de7024de26fe9f7d8b5fdbcb0826fc80a2fc14b588cbcac8fc880c8975
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
This section contains alternative standards to the classification of hazardous locations requirements in §§ 111.105-29, 111.105-31, 111.105-32, 111.106-9, and 111.106-11.
(a) Classification of hazardous locations may be in accordance with IEC 60092-502:1999 (incorporated by reference, see § 110.10-1 of this subchapter).
(b) If IEC 60092-502:1999 is chosen as an alternative standard as allowed in paragraph (a) of this section, it shall be used exclusively and not in combination with §§ 111.105-29, 111.105-31, 111.105-32, 111.106-9, and 111.106-11.
(c) If IEC 60092-502:1999 is chosen as an alternative standard as allowed by paragraph (a), the following ventilation system requirements apply in addition to the requirements of IEC 60092-502:1999:
(1) Tank vessels that carry combustible or flammable cargo, carriers of liquid-sulphur or inorganic acid, and hydrocarbon pump rooms must meet the requirements in § 32.60-20(c) of this chapter,
(2) Bulk liquefied flammable gas and ammonia carriers must meet the requirements in § 38.20-10 of this chapter, and
(3) Mechanical ventilation on all applicable vessels must be capable of at least 30 air changes per hour, based upon the gross volume of the space, and must be provided for the following spaces:
(i) Cargo handling or pump rooms, and
(ii) Other spaces where hazardous location classification is dependent upon ventilation.