46 CFR 113.25-9
§ 113.25-9 Location of general emergency alarm signal.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 113.25-9, § 113.25-9 Location of general emergency alarm signal, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227299
- Permanent ID
ys:prov:227299@1- SHA-256
04805e5851a7d317af59ecad7e342625745d54ccfe555d1e5bbcaf6f83082d9b
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
General emergency alarm signal must:
(a) Be located in passenger and crew quarters areas where they can alert persons in spaces where those persons may be maintaining, repairing, or operating equipment, stowing or drawing stores or equipment, or transiting, such as public spaces, work spaces, machinery spaces, workshops, galleys, emergency firepump room, bow thruster rooms, storage areas for paint, rope, and other stores, underdeck passageways in cargo areas, steering gear rooms, windlass rooms, holds of roll-on/roll-off vessels, and, except those that are accessible only through bolted manhole covers, duct keels with valve operators; and
(b) Be audible in the spaces identified in paragraph (a) of this section with all normally closed doors and accesses closed; and
(c) Be installed in cabins without loudspeaker installation. Other audible devices, such as electronic alarm transducers, are permitted.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.