yourstate.us
46 CFR 113.25-12

§ 113.25-12 Alarm signals.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 113.25-12, § 113.25-12 Alarm signals, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227302
Permanent ID
ys:prov:227302@1
SHA-256
ed6ccfe905d1eb9b53799abf1634d4551e9a425062707fc8127c17074c7b1134

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. (b) Electronic devices used to produce the general emergency alarm signal must meet the requirements of subpart 113.50 of this part. (c)(1) The minimum sound-pressure levels for the emergency-alarm tone in interior and exterior spaces must be a sound level of not less than 80 dB(A) measured at 10 feet on the axis; and (2) At least 10 dB(A) measured at 10 feet on the axis, above the background noise level when the vessel is underway in moderate weather unless flashing red lights are used in accordance with 46 CFR 113.25-10(b). (d) Alarm signals intended for use in sleeping compartments may have a minimum sound level of 75 dB(A) measured 3 feet (1 meter) on axis, and at least 10 dB(A) measured 3 feet (1 meter) on axis, above ambient noise levels with the ship under way in moderate weather.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.