46 CFR 113.43-5
§ 113.43-5 Power supply.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 113.43-5, § 113.43-5 Power supply, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227337
- Permanent ID
ys:prov:227337@1- SHA-256
667f2d85ca9ded771e3102a48dfb58f5e78c233e42d564bd739195a95680ed0b
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Each steering failure alarm system must be supplied by a circuit that:
(a) Is independent of other steering gear system and steering alarm circuits;
(b) Is fed from the final emergency power source through the emergency distribution panel in the wheelhouse, if installed; and
(c) Has no overcurrent protection except short-circuit protection by an instantaneous fuse or circuit breaker rated or set at 400 to 500 percent of:
(1) The current-carrying capacity of the smallest alarm system interconnecting conductors; or
(2) The normal load of the system.