yourstate.us
46 CFR 113.45-5

§ 113.45-5 General requirements.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 113.45-5, § 113.45-5 General requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227339
Permanent ID
ys:prov:227339@1
SHA-256
599d9fbf36661db5afae06f1eb1e79d20de1e60d1575ac529d123b0e5f56c391

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each refrigerated space that is accessible to the vessel's personnel and that can be locked from the outside so that it cannot be opened from the inside, must have an audible alarm system that can be operated from within the refrigerated space. (b) The alarm activator must be in the refrigerated space at its exit. (c) The audible signal must sound at a manned location. (d) If there is a common audible signal for more than one lockable refrigerated space, there must be an annunciator for locating the space from which the signal was initiated.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.