yourstate.us
46 CFR 113.50-5

§ 113.50-5 General requirements.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 113.50-5, § 113.50-5 General requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227342
Permanent ID
ys:prov:227342@1
SHA-256
6b5c4923f8013b4adc83a744a1505e1b70f01005e48e6df2a945140884c3e69f

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each vessel must have an amplifier-type announcing system that will supplement the general emergency alarm. This system must provide for the transmission of orders and information throughout the vessel by means of microphones and loudspeakers connected through an amplifier. If a decentralized-type system is used, its overall performance must not be affected by the failure of a single call station. This system may be combined with the general emergency alarm and fire detecting and alarm systems. The public address system must be protected against unauthorized use. (b) The announcing station must be located adjacent to the general emergency alarm contact maker or initiating device on the navigating bridge. (c) There must be a means to silence all other audio distribution systems at the announcing station. (d) The system may be arranged to allow broadcasting separately to, or to any combination of, various areas on the vessel. If the amplifier system is used for the general emergency alarm required by subpart 113.25 of this part, the operation of a general emergency alarm contact maker or initiating device must activate all speakers in the system, except that a separate crew alarm may be used as allowed by § 113.25-5(e)(2). (e) The amplifier, and any device used to produce the general emergency alarm signal, must be provided in duplicate. (f) The power supply must be in accordance with the requirements of §§ 113.25-6 and 113.25-7. (g) Each electrical subsystem in a weather location must be watertight or in a watertight enclosure and must meet Type 4 or 4X of NEMA 250 or IP 56 of IEC 60529:2013 (both incorporated by reference; see § 110.10-1 of this subchapter) requirements.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.