46 CFR 119.520
§ 119.520 Bilge pumps.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 119.520, § 119.520 Bilge pumps, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227565
- Permanent ID
ys:prov:227565@1- SHA-256
3655aed98081ab102b2736ca73b6887f040a364dd84b7965bbe28eeff841ac53
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each vessel must be provided with bilge pumps in accordance with § 56.50-55 in subchapter F of this chapter, with the following exceptions:
(1) Note 1 in Table 56.50-55(a) is not applicable and should be disregarded; and
(2) A non-self-propelled vessel must comply with § 56.50-55(a) in subchapter F of this chapter instead of § 56.50-55(b).
(b) In addition to the requirements of paragraph (a) of this section, a vessel of not more than 19.8 meters (65 feet) in length must have a portable hand bilge pump that must be:
(1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and
(2) Provided with suitable suction and discharge hoses capable of reaching the bilges of each watertight compartment, and discharging overboard.
(c) A second power pump is an acceptable alternative to a hand pump if it is supplied by a source independent of the first power bilge pump.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.