§ 130.450 Machinery alarms.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 130.450, § 130.450 Machinery alarms, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227883
- Permanent ID
ys:prov:227883@1- SHA-256
e42c79cc29bfbc258f4ba48180ae0830d755f48c244c89d25aa0f8d2f50070c8
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each alarm required by § 130.460 of this subpart must be of the self-monitoring type that will both show visibly and sound audibly upon an opening or break in the sensing circuit.
(b) The visible alarm must show until it is manually acknowledged and the condition is corrected.
(c) The audible alarm must sound until it is manually silenced.
(d) No silenced alarm may prevent any other audible alarm from sounding.
(e) Each OSV must be provided with means for testing each visible and audible alarm.
(f) Each OSV must provide battery power for the alarm required by § 130.460(a)(8) of this subpart.