46 CFR 131.560

§ 131.560 Weekly tests and inspections.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 131.560, § 131.560 Weekly tests and inspections, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/227919
Permanent ID
ys:prov:227919@1
SHA-256
e74fafc08ed6887c77fbabafe48294a9cb63702c30b73db8d86b8adcbad0ce98

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

The following tests and inspections must be carried out weekly: (a) Each lifesaving appliance and launching appliance must be visually inspected to ensure that it is ready for use. (b) Each engine of a lifeboat or a rescue boat must be run ahead and astern for not less than 3 minutes, unless the ambient temperature is below the minimal temperature required for starting the engine. (c) The general alarm system must be activated. (d) Each battery for starting the engine of a lifeboat or a rescue boat, or for energizing a searchlight, a fixed installation of a radio in a lifeboat, or a portable radio, must be brought up to full charge at least once a week if the battery is— (1) Of a type that requires recharging; and (2) Not connected to a device that keeps it continuously charged. (e) The transmitter of each fixed installation of a radio in a lifeboat and that of each portable radio must be tried out at least once a week with a dummy antenna load.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.