46 CFR 143.400
§ 143.400 Electrical systems, general.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 143.400, § 143.400 Electrical systems, general, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228250
- Permanent ID
ys:prov:228250@1- SHA-256
0545fabfcfe1bb036dd60869042147801c515b1d47282c406b6fcd700e84bfb2
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
(b) Installed electrical power source(s) must be capable of carrying the electrical load of the towing vessel under normal operating conditions.
(c) Electrical equipment must be marked with its respective current and voltage ratings.
(d) Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve.
(e) Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
(f) Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments.
(g) Electrical components that pose an electrical hazard must be in an enclosure.
(h) Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight.
(i) The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.