yourstate.us
46 CFR 147.50

§ 147.50 Fuel for cooking, heating, and lighting.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 147.50, § 147.50 Fuel for cooking, heating, and lighting, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228342
Permanent ID
ys:prov:228342@1
SHA-256
5266474b5edcb3460785aeee6588d70b7e35a39d174c0b961ff980cf0434804b

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Flammable and combustible liquids and gases not listed in this section are prohibited for cooking, heating, or lighting on any vessel, with the exception of combustible liquids on cargo vessels. (b) Fluid alcohol is prohibited for cooking, heating, or lighting on ferry vessels. Fluid alcohol burners, where wet primed, must have a catch pan not less than 3/4 of an inch deep secured inside of the frame of the stove or have the metal protection under the stove flanged up 3/4 of an inch to form a pan. (c) Containers of solidified alcohol must be secured on a fixed base. (d) Liquefied or non-liquefied gas is prohibited for cooking, heating, and lighting on ferry vessels, but may be used on other inspected vessels if the system in which it is used meets the applicable requirements of subpart 58.16 or subpart B of part 184 of this chapter, as appropriate, or is approved by the Commandant (CG-ENG). (e) Kerosene and commercial standard fuel oil No. 1, No. 2, and No. 3 are prohibited for cooking, heating, or lighting on ferry or passenger vessels, unless the following conditions are met: (1) Pressure or gravity feed must be used. (2) Where wet priming is used in a cooking device, the device must have a catch pan not less than three fourths of an inch deep secured inside the frame of the device or a metal protector under the device with a least a three fourths inch flange to form a pan. (3) Where wet priming is used, a non-flammable priming liquid must be used. (4) Fuel tanks for fixed stoves must be separated from the stove and mounted in a location open to the atmosphere or mounted inside a compartment with an outside fill and vent. (5) Fuel lines must have an easily accessible shut-off valve at the tank. (6) If the fuel tank is outside of a stove compartment, a shut-off valve must be fitted at the stove.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.