yourstate.us
46 CFR 148.51

§ 148.51 Temperature readings.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 148.51, § 148.51 Temperature readings, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228390
Permanent ID
ys:prov:228390@1
SHA-256
a0a67c765e6e19ddde93b6d02b09682826e4f1f6f79a69244f53e271444b5831

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

When Subpart D of this part sets a temperature limit for loading or transporting a material, apply the following rules: (a) The temperature of the material must be measured 20 to 36 centimeters (8 to 14 inches) below the surface at 3 meter (10 foot) intervals over the length and width of the stockpile or cargo hold. (b) The temperature must be measured at every spot in the stockpile or cargo hold that shows evidence of heating. (c) Before loading or transporting the material, all temperatures measured must be below the temperature limit set in Subpart D of this part.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.