46 CFR 148.435
§ 148.435 Electrical circuits in cargo holds.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 148.435, § 148.435 Electrical circuits in cargo holds, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228448
- Permanent ID
ys:prov:228448@1- SHA-256
067fb072066ec9cb75f8da00d507e51924d5e715b26ca52bd330d3ed1049d3f4
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
During transport of a material that Table 148.10 of this part associates with a reference to this section, each electrical circuit terminating in a cargo hold containing the material must be electrically disconnected from the power source at a point outside of the cargo hold. The point of disconnection must be marked to prevent the circuit from being reenergized while the material is on board.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.