46 CFR 151.03-25
§ 151.03-25 Flame screen.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 151.03-25, § 151.03-25 Flame screen, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228498
- Permanent ID
ys:prov:228498@1- SHA-256
85e6230cc5d7cb8987e2768c894bcc724953736f757a77418944d4e3677bfecb
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
A fitted single screen of corrosion-resistant wire of at least 30 by 30 mesh or two fitted screens, both of corrosion-resistant wire, of at least 20 by 20 mesh spaced not less than one-half inch or more than 1 1/2 inches apart.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.