yourstate.us
46 CFR 153.230

§ 153.230 Type I system.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 153.230, § 153.230 Type I system, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228637
Permanent ID
ys:prov:228637@1
SHA-256
8030a9c23c2e3bc56d244cc30ef90ec019ef886e1aab6021617085b4f43a2ba1

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

A type I containment system must meet the following requirements: (a) The vessel must meet the requirements in subpart F of part 172 of this chapter for a type I hull. (b) Except as described in § 153.235: (1) It may be no closer to the tankship's shell than 76 cm (approx. 29.9 in.); and (2) It may not be located in any part of the tankship subject to the damage described in Table 172.135 of this chapter for: (i) Collision Penetration, Transverse extent; and (ii) Grounding Penetration, Vertical extents from the baseline upward.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.